MegaBanner-Right

MegaBanner-Left

LeaderBoad-Right

LeaderBoard-Left

Home » Industry News » Water Engineering News » Reducing pumping system TCO – three valuable steps

Reducing pumping system TCO – three valuable steps

ENERGY costs remain a prevalent factor in the total cost of ownership (TCO) of industrial pumping systems, often accounting for 40% of overall consumption. However, it is possible to reduce the energy consumption of pumping by at least 30 percent if the appropriate energy management practices are put in place.

The first is step is for an organisation to acknowledge the high energy costs of pumping systems and introducing proper steps to implement cost reductions through efficiency improvements.  Furthermore, several barriers need to be addressed:

  • Lack of proper metrics – energy efficiency is traditionally not used in assessing performance; often energy procurement and efficient operations aren’t consistent or standardised metrics are not utilised;
  • Knowledge gap – a lack of awareness in energy efficiency opportunities is prevalent and as a result, potential savings and other benefits are missed; and
  • Fear of investment – operations personnel often struggle to present attractive (large or small) investments to their finance organisations.

What is required is the implementation of a sound energy management strategy which features practical and attainable steps to address the reduction of TCO, whilst realising the benefits of an efficient pumping system

Step 1 – Energy Efficiency Management

Industrial production cycles continue to be influenced by variables such as market demand, the weather, local regulations, and energy supply.  This means that factory and building operators need to understand how and when energy is used to minimise consumption and related costs.

In the case of pumping systems, efficiency is impacted by:

  • A mismatch between the pump deployed and the actual system requirement (i.e.: undersized or oversized); and
  • The improper use of throttling valves and damper technologies to control the flow of liquids.

Fortunately, the above can be remedied by implementing simple actions such as replacing fixed drives with variable speed drives.  Connected to a pump, a variable speed drive can control speed, pressure, and flow in conjunction with dynamic process and production requirements.

Step 2: Asset Management

The maintenance cost of physical assets can represent as much as 25 percent of TCO.  Maintenance, however, is non-negotiable as failure to do so can be catastrophic, resulting in costly downtime and production loss.

In pumping installations, many moving parts mean that proper maintenance of motors, drives, pumps, and associated pipes is crucial. Numerous steps can be taken to assure that maintenance costs are kept at a minimum while integrity of systems is kept stable:

  • All pumps should be operated within the parameters of a given pump’s specifications (often stated in the pump supplier’s instruction manual/data sheet);
  • Variable speed drives can help to keep the operating point close to the BEP (best efficiency point) and protect the pump against destructive forces generated by inefficiencies.
  • Monitoring the operating point of a pump and its efficiency provides diagnostics that can help predict when potential system problems will occur.

Step 3: Energy Cost Management

Building owners, water/wastewater, and oil and gas facility operators are presented with utility bills that have multiple components.

However, by implementing best practices for utility bill management, energy cost reduction can be realised.  Below are a few simple actions:

  • Review the utility contract to understand the charges associated with the bill and how it can be controlled.
  • Adjust the timing of energy usage from the peak rate period to the off-peak period as much as possible
  • Ensure the correct pump system size (drive + motor + pump).
  • Reduce the amount of non-revenue generating energy consumption.
  • Applying smart motor starting methods (Variable speed drives) to motor and pump systems

By pursuing best practices in energy efficiency management, asset management, and energy cost management, the TCO of pumping system networks can be reduced by up to 20 percent.

Moreover, one simple technology, the variable speed drive with embedded energy management functionality, has the capability of being a major contributor to achieving this TCO target.

 

To enquire about Cape Business News' digital marketing options please contact sales@cbn.co.za

Related articles

Unveiling the future of rail: SAHHA’s strategic vision for Heavy Haul, Pit-to-Port

SINCE its inception, the South African Heavy Haul Association (SAHHA) has been at the forefront of driving excellence and innovation and has achieved significant...

Vukile raises R1 billion in equity as it eyes growth opportunities

Vukile Property Fund will issue R1 billion of new ordinary shares, following a successful accelerated book build. The equity raised will boost Vukile’s financial...

MUST READ

City delivering real change

Behind every budget line, every policy, and every project there are real people, real challenges, and a shared future we are shaping. In a...

RECOMMENDED

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Strictly Necessary Cookies

Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.

If you disable this cookie, we will not be able to save your preferences. This means that every time you visit this website you will need to enable or disable cookies again.